Calabróir Brú Chliste PR9112
Paraiméadair Theicniúla
| Samhail | PR9112Calabróir Brú Chliste | |
| Tomhas Brú | Raon Tomhais | (-0.1~250) Mpa |
| Cruinneas taispeána | ±0.05%FS, ±0.02%FS | |
| Tomhas Reatha Leictrigh | Raon | ±30.0000mA |
| Íogaireacht | 0.1uA | |
| Cruinneas | ± (0.01% R.D + 0.003% FS) | |
| Tomhas Voltais | Raon | ±30.0000V |
| Íogaireacht | 0.1mV | |
| Cruinneas | ±(0.01%RD +0.003%FS) | |
| Luach Athraithe | Grúpa tomhais cumhachta/briseadh cumhachta | |
| Feidhm aschuir | Aschur srutha dhírigh | DC24V±0.5V |
| Comhshaol Oibriúcháin | Teocht Oibre | (-20~50) ℃ |
| Teocht Choibhneasta | <95% | |
| Teocht Stórála | (-30~80)℃ | |
| Cumraíocht an tSoláthair Cumhachta | Mód soláthair cumhachta | Ceallraí litiam nó soláthar cumhachta |
| Am Oibriúcháin Ceallraí | 60 uair an chloig (24V gan ualach) | |
| Am muirir | Thart ar 4 uair an chloig | |
| Táscairí eile | Méid | 115mm × 45mm × 180mm |
| Comhéadan cumarsáide | breiseán eitlíochta trí chroí speisialaithe | |
| Meáchan | 0.8KG | |
Príomhfheidhmchlár:
1. Calabraigh an tarchuradóir brú (brú difreálach)
2. Calabraigh an lasc brú
3. Fíoraigh an tomhasaire brú beachtais, an tomhasaire brú ginearálta.
Gné Táirge:
1. Feidhm oibreora láimhe tógtha isteach, is féidir an tarchuradóir brú cliste HART a chalabrú. (roghnach)
2. Taispeántas criostail leachtach dúbailte-sraithe le soilsiú cúil.
3.mmH2O, mmHg, psi, kPa, MPa, Pa, mbar, barra, kgf/c㎡, athraigh idir naoi n-aonad brú.
4. Le feidhm aschuir DC24V.
5. Le tomhas reatha, voltais.
6. Tomhas le toirt lasctha.
7. Le comhéadan cumarsáide. (roghnach)
8. Cumas stórála: 30 comhad ríomhaire san iomlán, (50 taifead sonraí de gach comhad)
9. Taispeántas leachtach criostail scáileáin mhóir
Cumraíocht Bogearraí:
Is é bogearraí PR9112S an chórais fíoraithe brú an bogearra tacaíochta dár gcóras digiteachcalabróir brútáirgí sraith inár gcuideachta, is féidir taifid bhailiúcháin sonraí a dhéanamh, foirm a ghintear go huathoibríoch, ríomh earráide uathoibríoch, deimhniú priontála.
1.Tábla Roghnúcháin Raon Brú Gnáthaimh
| Níl. | Raon Brú | Cineál | Rang cruinnis |
| 01 | (-100~0) kPa | G | 0.02/0.05 |
| 02 | (0~60)Pa | G | 0.2/0.05 |
| 03 | (0~250)Pa | G | 0.2/0.05 |
| 04 | (0 ~ 1) kPa | G | 0.05/0.1 |
| 05 | (0 ~ 2) kPa | G | 0.05/0.1 |
| 06 | (0 ~ 2.5) kPa | G | 0.05/0.1 |
| 07 | (0 ~ 5) kPa | G | 0.05/0.1 |
| 08 | (0 ~ 10) kPa | G | 0.05/0.1 |
| 09 | (0 ~ 16) kPa | G | 0.05/0.1 |
| 10 | (0 ~ 25) kPa | G | 0.05/0.1 |
| 11 | (0 ~ 40) kPa | G | 0.05/0.1 |
| 12 | (0 ~ 60) kPa | G | 0.05/0.1 |
| 13 | (0 ~ 100) kPa | G | 0.05/0.1 |
| 14 | (0 ~ 160) kPa | G/L | 0.02/0.05 |
| 15 | (0 ~ 250) kPa | G/L | 0.02/0.05 |
| 16 | (0 ~ 400) kPa | G/L | 0.02/0.05 |
| 17 | (0 ~ 600) kPa | G/L | 0.02/0.05 |
| 18 | (0 ~ 1) MPa | G/L | 0.02/0.05 |
| 19 | (0 ~ 1.6) MPa | G/L | 0.02/0.05 |
| 20 | (0 ~ 2.5) MPa | G/L | 0.02/0.05 |
| 21 | (0 ~ 4) MPa | G/L | 0.02/0.05 |
| 22 | (0 ~ 6) MPa | G/L | 0.02/0.05 |
| 23 | (0 ~ 10) MPa | G/L | 0.02/0.05 |
| 24 | (0 ~ 16) MPa | G/L | 0.02/0.05 |
| 25 | (0 ~ 25) MPa | G/L | 0.02/0.05 |
| 26 | (0 ~ 40) MPa | G/L | 0.02/0.05 |
| 27 | (0 ~ 60) MPa | G/L | 0.05/0.1 |
| 28 | (0 ~ 100) MPa | G/L | 0.05/0.1 |
| 29 | (0 ~ 160) MPa | G/L | 0.05/0.1 |
| 30 | (0 ~ 250) MPa | G/L | 0.05/0.1 |
Nótaí: G=GásL=Leacht
2.Tábla Roghnúcháin Raon Brú Ilchodach:
| Níl. | Raon Brú | Cineál | Rang cruinnis |
| 01 | ±60 Pa | G | 0.2/0.5 |
| 02 | ±160 Pa | G | 0.2/0.5 |
| 03 | ±250 Pa | G | 0.2/0.5 |
| 04 | ±500 Pa | G | 0.2/0.5 |
| 05 | ±1kPa | G | 0.05/0.1 |
| 06 | ±2kPa | G | 0.05/0.1 |
| 07 | ±2.5 kPa | G | 0.05/0.1 |
| 08 | ±5kPa | G | 0.05/0.1 |
| 09 | ±10kPa | G | 0.05/0.1 |
| 10 | ±16kPa | G | 0.05/0.1 |
| 11 | ±25kPa | G | 0.05/0.1 |
| 12 | ±40kPa | G | 0.05/0.1 |
| 13 | ±60kPa | G | 0.05/0.1 |
| 14 | ±100kPa | G | 0.02/0.05 |
| 15 | (-100 ~160) kPa | G/L | 0.02/0.05 |
| 16 | (-100 ~250) kPa | G/L | 0.02/0.05 |
| 17 | (-100 ~400) kPa | G/L | 0.02/0.05 |
| 18 | (-100 ~600) kPa | G/L | 0.02/0.05 |
| 19 | (-0.1~1)Mpa | G/L | 0.02/0.05 |
| 20 | (-0.1~1.6) Mpa | G/L | 0.02/0.05 |
| 21 | (-0.1~2.5)Mpa | G/L | 0.02/0.05 |
Nótaí:
1. Is féidir le raon páirteach brú iomlán a dhéanamh
2. Raon cúitimh teochta uathoibríoch: (-20 ~ 50 ℃)
3. Éilíonn meán aistrithe brú neamh-chreimneach